CARLISLE® Induction system
Experience the new dimension of mechanical fixing with the CARLISLE® induction fixing system and our HERTALAN® EASY COVER membranes.
This innovative system uses special magnetic coated plates to secure the HERTALAN® EPDM membranes and insulation to the roof construction without having to penetrate the roof membrane.
This innovative installation method means that HERTALAN® EPDM membranes can be removed without damage at the end of their service life, supporting a circular approach to construction.
Transforming EPDM membrane installation
%3Aquality(75)%3Fupdated_at%3D2025-02-13T08%3A32%3A56.892Z&w=3840&q=75)
Installation Instructions
EFFICIENT INSTALLATION: The fixings are positioned precisely where they are actually needed reducing number of fixings and installation time.
In contrast to traditional methods involving seam fixing, field fixing with the induction process distributes the wind load evenly over the EPDM-membranes. This prevents any asymmetrical force impact on the fastening plates and seams.
The position of the fastening plate is defined based on the wind load calculations for the property and distributed in the roof system. As a result, despite mechanical fixing, larger membranes can be used and a clear reduction is achieved in the seam proportions and seam overlap compared to conventional systems fixed in place by mechanical means
%3Aquality(75)%3Fupdated_at%3D2023-02-16T10%3A02%3A01.128Z&w=3840&q=75)
What is circular construction?
Circular construction is a methodology that puts the reuse and recycling of materials at the heart of the specification process. This means selecting products with a long service life that can be dismantled at the end of their initial use and returned to the value chain. It is a philosophy that is seeing the drive for future-proof construction come of age.
HERTALAN® EPDM roofing systems are a good example. According to a long-term study by the SKZ, the material EPDM has a projected service life of more than 70 years and is known as a durable roofing technology. The induction system builds on this by allowing roofing contractors to fix the EPDM membrane so that it can be removed cleanly at the end of its service life for reuse or recycling.